Communication Manager Maintenance-Object Repair Procedures
1138 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes (Multicarrier)
Always investigate tests in the order presented in the following table. By clearing error codes
associated with one test, you may clear errors generated from other tests in the sequence.
Table 390: EMG-XFER Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0Any AnyAnytest environment UU
1 0 Emergency Transfer
query (#124)
MAJ ON test environment UU r 3
257 0 Emergency Transfer
query (#124)
WRN ON test environment UU r 3
Table 391: System Technician-Demanded Tests: EMG-XFER (Multicarrier Cabinets)
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
1
Battery & Battery Charger Query test (#5) (a)XXND
AC Power Query test (#78) (b
)XXND
OLS Query test (Carrier E) (#127) (c
)XXND
OLS Query test (Carrier D) (#127) (c
)XXND
OLS Query test (Carrier A) (#127) (c
)XXND
OLS Query test (Carrier B) (#127) (c
)XXND
OLS Query test (Carrier C) (#127) (c
)XXND
Emergency Transfer Query test (#124) X X ND
Cabinet Sensors Query test (#122) (d
)XXND
1 of 2