101 FAIL Data was not sent from port 3 to port 2 successfully in asynchronous
mode.
1. Reset the circuit pack using busyout board location, reset
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
102 FAIL Data was not sent from port 2 to port 3 successfully in synchronous
mode.
1. Reset the circuit pack using busyout board location, reset
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
103 FAIL Data was not sent from port 3 to port 2 successfully in synchronous
mode.
1. Reset the circuit pack using busyout board location, reset
board location, and release board location.
2. Test the port again using test port location (02) l.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test digital port digital trunk testing capability is
operating correctly.
Table 636: Test #565 Digital Port Sanity Test (continued)
Error
Code
Test
Result
Description / Recommendation