PE-BCHL (PRI Endpoint Port)
Issue 1 June 2005 1785
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1 interface circuit
pack to assure that the port’s translation is correct. The port audit operation verifies the
consistency of the current state of port kept in the UDS1 interface circuit pack and in the switch
software.
Table 660: Test #36 Audit and Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS Port translation has been updated successfully. The current port states
kept in the UDS1 interface circuit pack and switch software are consistent.
If the port is busied out, the test will not run, but will return PASS. To verify
that the port is in-service:
1. Enter status pri-endpoint extension to verify that the port is
in-service. If the port is in-service, no further action is necessary. If the
port is out-of-service, continue to Step 2.
2. Enter release pri-endpoint extension or release port
location command to put port back into in-service.
3. Retry the test command.