Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
596 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
TDM bus itself. If TDM bus maintenance tests find no problems with the bus, then it is
either the port board or the EAA. It may be simpler to replace the port board than to request
a PNC interchange. However, if it is not clear which port board may be at fault or
maintenance is being performed remotely, verify that the EAA is not at fault by executing a
PNC interchange. If the interchange solves the problem, then the EAA is faulty. If the
problem persists after the interchange, but TDM bus maintenance finds no problem, then
the port board is faulty.
Error Log Entries
Whenever a PNC interchange takes place, an error is logged against PNC-DUP with a code
that conveys information about the cause of the interchange and which PNC became active.
There are no alarms associated with PNC-DUP errors, but there should be an alarm against the
PNC component that caused the interchange. There are no PNC-DUP test sequences, but
status pnc provides information regarding the status of the PNCs. The information in
Table 193: Error Code descriptions and Aux Data correlations
on page 596 and
Table 194: Error Log Encode Field Decoding
on page 597 can help to identify which areas of
the Alarm Log to investigate to find the source of the problem.
Table 193: Error Code descriptions and Aux Data correlations
Error
Code
Description Aux Data
1
1. The Aux Data indicates which PNC became active after the PNC interchange: “0” denotes PNC-A; “1”
denotes PNC-B.
00000 Error in generating error code None
1cxpp Spontaneous Interchange in response to a constraint for A-PNC Active PNC
2cxpp Spontaneous Interchange in response to a constraint for B-PNC Active PNC
51000 Spontaneous Interchange at expiration of SOH validation timer Active PNC
52000 Spontaneous Interchange upon PNC UNLOCK Active PNC
53000 Spontaneous Interchange at completion of Global Refresh Active PNC
60801 PNC Demand Interchange Active PNC
60800 PNC Demand Interchange with override Active PNC