Communication Manager Maintenance-Object Repair Procedures
484 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ASAI-EPT
S8700 | 8710 / S8500
The maintenance strategy for this endpoint MO is built on maintenance facilities offered in the
Avaya ISDN-BRI protocol and in the ASAI adjuncts. Currently there are no facilities in the
protocol that provide for maintenance of set data features.
The TN800 is a PC-based platform that allows interaction of multiple applications with
Communication Manager at any time. Communication Manager (native mode) supports
emulation of three types of port MOs on this board. The type of ports to be emulated is defined
by the applications running on the TN800.
Note:
Note: If the TN800 is emulating BRI, the software/firmware supports up to 12 ports, but
only 8 of the 12 ports can be administered at any one time.
Error Log Entries and Test to Clear Values
MO Name in Alarm Log Alarm
Level
Initial Command to Run Full Name of MO
ASAI-EPT MAJ
1
1. The alarm level for ASAI adjuncts is adminisered using set options. The alarm level can be set
independently for on- and off-board alarms toWARNING, MINOR, or MAJOR for every ASAI
adjunct in the system.
test station extension ASAI-Adjunct
Table 146: ASAI-EPT Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
ASAI-EPT
On/ Off
Board
Test to Clear Value
0 (a
) 0 Any Any Any test ASAI-ADJ
2 (b
)2-102None
257 (c
) Any BRI Layer 3 query MAJ
WRN
1
OFF test station ext r 2
test data-module ext r 2
351 (d
) 0 none WRN OFF busyout and release station
513 (e
)0 None
769 (f
)0 None MAJ OFF
2561 (g
)0 None
1 of 2