Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
2532 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Wideband Access Endpoint interface, and because faults can occur end-to-end,
troubleshooting procedures based on an end-to-end view of the network is required.
Wideband access endpoint port maintenance provides a strategy to maintain a wideband
access endpoint port via a port on the Universal DS1 interface circuit pack or the MM710 DS1
Interface Media Module hardware. The maintenance strategy covers logging wideband access
endpoint port hardware errors, running tests for port initialization, periodic and scheduled
maintenance, demand tests, and alarm escalation and resolution. Two different port service
states are specified in the wideband access endpoint port maintenance:
out-of-service: the port is in a deactivated state and cannot be used for calls
in-service: the port is in an activated state and can be used for calls
If the UDS1 Interface circuit pack or the MM710 DS1 Interface Media Module is out of
service, every port on it is taken out of service, and a Warning alarm is raised.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 18: the wideband access endpoint has been busied out by busyout
access-endpoint extension. No calls can be made to this extension.
Table 900: Wideband Access Endpoint Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test access-endpoint extension
sh r 1
18 (a
)0 busyout access-endpoint
extension
WRN OFF release access-endpoint
extension
130 (b
)None WRNONtest access-endpoint extension
1281 (c
) Conference Circuit (#7) MIN ON test access-endpoint extension l
r 4
1537 (d
) NPE Crosstalk Test (#6) MIN ON test access-endpoint extension l
r 3
1793 (e
)None test board location long
3840 (f
) Any Port Audit and Update (#36)