Communication Manager Maintenance-Object Repair Procedures
1528 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
r. Error Type 3841: The circuit pack detected a transient hardware logic error (for example,
program logic inconsistency). This error resolves when no faults are detected for 100
minutes. The value in Aux Data field (4358) indicates the type of hardware problem.
s. Error Type 3842: Bad Translation RAM Location Found error. The call continues by using
another translation location. This error is not service-affecting and requires no action.
t. Error Type 3843: LAN Receive Parity error. The circuit pack detected an error in a received
frame from the packet bus. These errors are most likely caused by a packet-bus problem,
but may be due to a circuit-pack fault.
1. Determine whether the problem is isolated to this circuit pack or the problem is caused by
packet-bus faults (see PKT-BUS (Packet Bus)
on page 1790).
u. Error Type 3999: The circuit pack sent a large number of control-channel messages to the
switch within a short period of time.
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logical link
Error Type 1538
(hyperactivity)
also present?
Then the system:
Y Takes the circuit pack out-of-service due to hyperactivity.
N Does not take the circuit pack out-of-service, but the circuit pack
has generated 50% of the messages necessary to be considered
hyperactive. This may be normal during heavy traffic periods.
2 of 2