PRI-CDR (Call Detail Recording Link)
Issue 1 June 2005 1907
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 18: the CDR link is busied out and the CDR link is torn down.
c. Error Type 257: Link Retry test (#215) failed. An error was detected when setting up the
link. See the preceding section Procedures for Restoring the CDR Link
on page 1906 for
resolution.
d. Error Type 513: the CDR physical link is down for one of the following reasons:
Cable to the CDR output device is disconnected.
CDR output device is powered off.
The data extension where the CDR output device connects to has been busied out or
there is a scheduled daily interchange.
1. Check the connectivity of wire and cable among wall jacket, data module, and the CDR
output device.
2. Enter status data extension and verify that the data extension of the CDR output
device is in the in-service/idle state. If the data extension is not available, see Procedures
for Restoring the CDR Link on page 1906 for resolution.
Table 697: CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test cdr-link primary |
secondary sh
18 (b
)0 busyout cdr-link
primary|secondary
WRN OFF release cd-link primary
| secondary
257 (c
) Any Link Retry test (#215) MIN
1
WRN
1. Minor alarms may be downgraded to Warning alarms based on the value used in set options.
OFF test cd-link primary |
secondary l
513 (d
) test cdr-link primary |
secondary
1025 (e
)
1281 (f
)Any