Communication Manager Maintenance-Object Repair Procedures
1258 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Expansion Interface Fiber Out-of-Frame (FOOF) Query Test (#238)
This test is nondestructive.
This test is a request to an EI circuit pack to determine whether it is currently detecting the
framing sequence on the incoming fiber’s data stream. If it cannot detect this framing signal, the
EI circuit pack will not be able to establish a link with the opposite EI or SNI circuit pack.
For EI-to-EI fiber links, this test is run on both EI circuit pack endpoints of the fiber link.
Table 437: Test #238 Expansion Interface Fiber Out-of-Frame Query Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error (software).
1. Run test board location separately for each EI endpoint on this
fiber link and follow the procedures for this test in the EXP-INTF
(Expansion Interface Circuit Pack) on page 1176 section of the
maintenance manual.
2. If the test continues to abort or fail, escalate the problem.
1033 ABRT The EI circuit pack does not have a fiber link administered to it. There is not
sufficient data to run test. Because test fiber-link was run, the
expansion interface should be administered on a fiber link, therefore this
must be a software problem.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Run test board location separately for each EI endpoint on this
fiber link and follow the procedures in EXP-INTF (Expansion Interface
Circuit Pack) on page 1176.
2100 ABRT System resources required to run this test are not available.
1. Run test board location separately for each EI endpoint on this
fiber link and follow the procedures in EXP-INTF (Expansion Interface
Circuit Pack) on page 1176.
2500 ABRT Internal system error
1. Run test board location separately for each EI endpoint on this
fiber link and follow the procedures in EXP-INTF (Expansion Interface
Circuit Pack) on page 1176.
1 of 2