OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 June 2005 1745
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface circuit
pack to assure that the trunk’s translation is correct. Translation updates include the following
data: line type, dial type, timing parameters, and signaling bits enabled. The port audit operation
verifies the consistency of the current state of the trunk as kept in the DS1 Interface circuit pack
and in the switch software.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board
is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list
config, and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long.
This should re-establish the linkage between the internal ID and the port.
If not, ensure that there is a valid board inserted.
Table 645: Test #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
5 of 5
Table 646: Test #36 Audit and Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3