EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005 1231
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 3 times.
2100 ABRT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
9999 ABRT EI circuit pack reset successfully. Could not perform initialization test
results query because link to PN is not up.
1. Execute release board PCSS. Wait one minute. Enter display
error. If you see Error Type 2049 logged against this EI circuit pack,
then the EI Test has failed with an error code equal to the aux data of
this entry. Otherwise, the initialization tests have passed.
12000 ABRT EI circuit pack reset successfully. Response to the initialization test results
query was not received within the allowable time period.
12100 ABRT EI circuit pack reset successfully. System resources required to run
initialization test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
12026 ABRT EI circuit pack reset successfully. It responded with an unknown reply to
the query for the results of its initialization tests.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort, replace the circuit pack or transceiver.
1 FAIL The EI did not successfully reset.
1. If the EI circuit pack is in the PN, the PN’s Maintenance board may be
holding the EI circuit pack reset. Attempt to rectify this condition by
executing test maint P long on the Maintenance board in the
same PN.
2. If step 1 was not successful in releasing the EI circuit pack, temporarily
remove the PN’s Maintenance circuit pack.
3. Enter reset board PCSS.
4. If reset continues to fail, replace circuit pack.
5. Insert PN’s Maintenance circuit pack if it was removed.
Table 417: Test #224 Expansion Interface Test (continued)
Error
Code
Test
Result
Description / Recommendation