Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
624 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
18 Multiplexer
Section Alarm
Indication
Signal:
MS_AIS
There is a major problem on the far end (between multiplexer
section [MUX] and the switch) that prohibits the circuit pack from
sending a valid signal.
1. See if the ports at the MUX and/or the ATM switch are
connected snugly.
2. Run test board location.
3. If Test #1259 fails with Error Code 18, connect a fiber
back-to-back in a looped mode (one strand of fiber connecting
the transmit transceiver to the receive transceiver of the board)
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack; if
the error persists, escalate the problem.
19 Multiplexer
Section
Remote Defect
Indicator:
MS_RDI
The far end is detecting a major problem with the signal that this
board is transmitting.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-TRK board) is the same as
the ATM-TRK circuit pack’s cable interface
2. Run test board location.
3. If Test #1259 fails with Error Code 19, connect a fiber
back-to-back in a looped mode (one strand of fiber connecting
the transmit transceiver to the receive transceiver of the board)
and see if the amber LED flash goes away.
4. If it does the problem is off-board.
5. If the amber LED continues to flash, replace the circuit pack; if
the error persists, escalate the problem.
20 Loss of pointer:
LOP
ATM framer chip is unable to access the payload part of the signal.
1. Reset the board with reset board location.
2. If the error persists replace the board.
21 Path Signal
Error (PSL)
(STM1/
SONET)
The incoming signal payload is not set up for transmission of ATM
data.
1. Make sure the ATM switch port (or a MUX port, if present
between ATM switch and the ATM-TRK board) is the same as
the ATM-TRK circuit pack’s cable interface.
Table 209: Error type 1281 Aux Data and repair procedures (continued)
Aux
Data
Alarm
Description
Repair procedure
2 of 3