Communication Manager Maintenance-Object Repair Procedures
890 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1000 ABRT System resources required for this test are not available.
The port may be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error
log for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
1001 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of- service due
to TDM BUS error. Use status health to determine whether the
system is experiencing heavy traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some Tone
Detectors may be out of service.
1. Enter list measurements tone-receiver to display information
about the tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
Table 304: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4