Communication Manager Maintenance-Object Repair Procedures
1804 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
PKT-INT and System Reliability
S8700 IP
A PKT-INT module resides on each IPSI board. On an S8700 IP Connect, there is a duplicated
server, and one server is in active mode and one server is on standby. The control network(s)
for S8700 IP Connect may be implemented in a simplex, see Figure 105: IP Connect Duplex
Reliability - Simplex Control Network on page 1805, or a optional duplicated configuration.
There is only one PKT-INT per port network.
Note:
Note: Duplicated control networks require G650 media gateways (not G600) because
the G600 does not support duplicated clocks. The clock is a component of the
TN2312 IPSI.