Communication Manager Maintenance-Object Repair Procedures
370 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1018 ABRT Test disabled by administration.
1. To enable the test for the particular analog station, enter change
station extension.
2. Enter y in the Test field.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The reflective loop-around test failed. This causes noisy or unreliable
connections or other users calling this port may hear an echo.
1. Replace the circuit pack.
PASS The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by examining the
station.
Table 102: Test #161 Loop-Around Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2