Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
VC-SUMPT
Issue 1 June 2005 2529
1002 ABRT The system could not allocate time slots for the test. The traffic load on the
system is very high, or time slots are out-of-service due to TDM-BUS
errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a Tone Detector for the test, the system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port has been seized by a user for a valid call. Use status station
for the station associated with this port to determine whether the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABRT Response to the test request was not received from the VC-BD circuit
pack within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports
are idle. Reset the circuit pack by issuing busyout board
location and reset board location.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2103 ABRT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
0 FAIL The TDM Loop-Around test failed.
Table 899: Test #1100 VC Summer Port Local TDM Loop-Back Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3