MEDPRO (Media Processor MAPD Circuit Pack)
Issue 1 June 2005 1543
Control Channel Loop-Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage, and verifies its records.
IP Address Query (#1371) X X D
NIC Query test (#1383) X X ND
PING test (#1379) X X ND
Windows 2000 Reset (#1381) X D
1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
D/ND
1
2 of 2
Table 565: Test #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, and if the circuit pack is one of the Port
circuit packs, replace the circuit pack.
PASS Communication with this circuit pack is successful.
1 of 2