Communication Manager Maintenance-Object Repair Procedures
828 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This result could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, an insane board is inserted, or the board is
hyperactive.
1. Verify that the board’s translations are correct. Enter list config,
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter busyout
board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.
Note:
Note: Hyperactivity causes some special problems with the
sequence suggested above.If the ports are translated after
issuing list config but the Vintage field reports that
there is no board (when there really is a board), then
busyout board and release boards will not work (even
though reset board location will work). The software
will put the hyperactive board back in service after the
hyperactivity clears.