Communication Manager Maintenance-Object Repair Procedures
2288 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1020 ABRT The test did not run due to an already existing error on the specific port or
due to a more general circuit pack or media module error.
1. Examine the error log for existing errors against this port or the circuit
pack or media module and attempt to diagnose the already existing
error.
2. Retry the test.
1040 ABRT The test is invalid for this trunk port because it is administered as an
access endpoint.
1. Use display port location to verify that this port is administered
as an access endpoint. In this case the test should abort.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABRT/
FAIL
At least one of the following errors is found on the DS1 circuit pack or
media module: 1281 – Loss of Signal, 1793 – Blue alarm, 2049 – Red
alarm, 2305 – Yellow alarm, or 1537 – Hyperactivity.
1. Look for the previous Error Types in the Hardware Error Log, and
follow the procedures given in the appropriate DS1-BD, UDS1-BD, or
MG-DS1 maintenance documentation for the listed Error Types.
Earlier G1 software versions reported Error Code 2053 as a FAIL.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Table 818: Test #136 DS1 Tie Trunk Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation
3 of 5