INADS (INADS Link)
Issue 1 June 2005 1353
4 0 The alarm receiver did not answer the test call.
1. Verify that the alarm receiver is up and running.
2. Verify the accuracy of the alarm receiver’s phone number and the
system’s product ID using the Maintenance-Related System
Parameters screen.
3. Enable alarm origination using the Maintenance-Related System
Parameters screen.
4. Test the SYSAM (System Access Maintenance) by issuing test
maintenance a | b.
5. Retry the command.
5 0 The alarm receiver’s phone number is not assigned.
1. Assign the alarm receiver’s phone number via the Maintenance-Related
System Parameters screen.
2. Retry the command.
6 0 The alarm receiver did not return an acknowledgment for the “test inads
alarm” message.
1. Verify the accuracy of the alarm receiver’s phone number and the
system’s product ID via the Maintenance-Related System Parameters
screen.
2. Verify that the alarm receiver is up and running.
3. Retry the command.
7 0 The alarm receiver returned a negative acknowledgment for the TESTING
INADS LINK message.
1. Verify that the product IDs match in the customer’s switch and the alarm
receiver’s database. Use the Maintenance-Related System
Parameters screen to identify the product ID of the switch.
2. Rerun the test.
8 0 Internal system error. System received an invalid return code.
9 0 Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 473: INADS Link Test Error Log Entries (continued)
Error
Code
Test
Result
Description / Recommendation