Communication Manager Maintenance-Object Repair Procedures
2034 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
TPN Test (#779)
This test is nondestructive.
This test queries the SNC circuit pack for status of the ROM and internal RAM background tests
for the TPN microcontroller.
Table 743: TEST #779 TPN Test
Error
Code
Test
Result
Description / Recommendation
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302 ABRT Software received unexpected message data from the SNC circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303 ABRT The SNC circuit pack responded that the software test requested is not
valid.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABRT SNC circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.