VC-DSPPT
Issue 1 June 2005 2521
VC Port Reset DSP Test (#1106)
This test is destructive.
This test resets the VC-DSPPT and the DSP associated with it. As part of the reset procedure,
the VC-DSPPT will execute a series of self-tests on the hardware. If these self-tests fail, the test
will fail; otherwise the test will pass.
Before executing the test, the VC-DSPPT must be busied out by executing busyout port
location. After the completion of the test, the VC-DSPPT must be released by executing
release port location.
Table 895: Test #1106 VC Port Reset DSP Test
Error
Code
Test
Result
Description / Recommendation
1000 ABRT System resources required to run this test are not available, or the port may
be busy with a call.
1. Retry the command at 1-minute intervals up to 5 times.
1015 ABRT The VC-DSPPT is not busied out.
1. Busyout the VC-DSPPT by executing busyout port location,
then retry the test.
2000 ABRT Response to the test was not received from the VC-DSPPT within the
allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If this result occurs again, replace the circuit pack.
2012 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The reset of the VC-DSPPT was unsuccessful.
1. Replace circuit pack.
PASS The VC-DSPPT was successfully reset.
1. Release the VC-DSPPT by executing release port location.