CAB-EXFR (emergency transfer)
Issue 1 June 2005 741
Emergency Transfer Query test (#1532)
There is only one test associated with the MO CAB-EXFR. The emergency transfer query test
queries the maintenance module on the TN2312BP IPSI to determine if the emergency transfer
is set in MANUAL-ON or MANUAL-OFF mode. If emergency transfer is set to MANUAL-ON, a
major alarm is generated. If emergency transfer is set to MANUAL-OFF, a warning alarm is
generated.
Table 252: Test 1532 Emergency transfer query
Error
code
Test
result
Description and recommendation
1000 ABRT This is an internal system error.
1. Repeat the command at one-minute intervals 1 to 3 times.
2000 ABRT The response to a query was not received in the time allowed.
1. Repeat the command at one-minute intervals 1 to 3 times.
1 FAIL The emergency transfer is set to Manual-Off.
1. Use the status cabinet cab or status health cab command
to display the status of the emergency transfer select switch:
● “on” means that emergency transfer was manually activated by the
set emergency-transfer on command.
● “off” means that emergency transfer was manually deactivated by the
set emergency-transfer off command.
● “auto+” means that the system has a serious alarm that causes
Communication Manager to activate emergency transfer.
● “auto-” means that emergency transfer is not active and is not being
controlled by the set emergency transfer command.
2. If "off", enter set emergency auto cab command to return control
of emergency transfer to Communication Manager.
1 of 3