Server Alarms
54 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Back to: Hardware MOs Server-related alarms
DAJ1/DAL1 Alarms in S8700 Media Server
S8700 | 8710 only
Table 13: DAJ1/DAL1 Alarms in Media Server
on page 54 describes the Duplication Memory
card MO’s alarms and their troubleshooting procedures.
Table 12: TEST DAJ1/DAL1 Local Loop Test
Error Code Test Result Description / Recommendation
Open failed
to MDD
ABRT The MDD is the system driver that communicates with the
Duplication Memory board. If this driver cannot be opened, the
board’s registers cannot be read.
This is a system type error, try again.
System Error
MDD failed
to return
data
ABRT The test ran, but for some reason the MDD could not return
data.
This is a system type error, try again.
Loop-around
test failed
FAIL The last address received does not match the address that was
written, or the last data received does not match the data that
was written.
Table 13: DAJ1/DAL1 Alarms in Media Server
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
2 WRN “Single-bit EDC test (bad SB err cnt)” — Single-bit SDRAM error occurred
20 times.
Software automatically clears the single-bit error register. This is a
log-only indication of the error’s occurrence.
1. Manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
1 of 2