HYB-LINE (Hybrid Line)
Issue 1 June 2005 1343
Hybrid Line Remote Digital Looparound
Test (#59)
This test checks the digital control pair from the port circuit to the terminal. The on-board
microprocessor sends a message to the terminal and checks for a proper return message. This
test is repeated three times, with two out of the three attempts passing being sufficient for this
test to pass. This test will run if the station is in service or out of service.
Table 469: Test #59 Hybrid Line Remote Digital Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 ABRT A request for a remote station audit aborted even though every internal
resource was correctly allocated.
1. Look in the error log for Error Type 18 (port busied out) for this port. If
this Error Type is present, release the port via release port
location or release station extension, and then run the test
again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port may
be busy with a valid call.
1. Use display port location to determine the station extension
number of the port. Use status station to determine the service
state of the port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.