SYS-PRNT (System Printer)
Issue 1 June 2005 2185
Link Retry Test (#215)
This test sends a message to the System Printer management software process instructing it to
make a data call to the extension connected to the printer. If the System Printer link is already
up, this test passes without making any data call.
Table 779: TEST #215 Link Retry Test
Error
Code
Test
Result
Description / Recommendation
10
20
ABRT Internal system error.
1. Retry the command at 1-minute intervals up to two times.
30 ABRT Internal system error.
1. See Procedures for Restoring the System Printer Link
on page 2181 for
recommended maintenance strategy.
1010 ABRT The System Printer Link has been busied out.
1. Enter release sp-link to release the System Printer Link from the
busyout state.
2. Enter test sp-link long to execute the test.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to five times.
FAIL The System Printer Link CANNOT be established.
1. See Procedures for Restoring the System Printer Link
on page 2181 for
recommended maintenance strategy.
PASS The System Printer Link is up.