Communication Manager Maintenance-Object Repair Procedures
1984 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1020 ABRT The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
2. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This
causes noisy and unreliable connections.
1. Retry the test.
2. If the test continues to fail, then replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported
troubles on this port should be investigated using other port tests and by
examining the Error Log.
Table 728: TEST #7 Conference Circuit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2