Communication Manager Maintenance-Object Repair Procedures
1400 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000 ABRT Response to the test was not received within the allowable time. Retry the
command at 1 minute intervals a maximum of 3 times.
1. If this result occurs repeatedly, attempt to reset the circuit pack with
busyout board location and reset board location.
2. If this result occurs again, after resetting the board, replace the circuit
pack.
2012 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABRT Internal system error.
Retry the command at 1-minute intervals up to 3 times.
2801 ABRT Could not find the IP address for this board.
1. Use the change ip-interfaces location to administer an IP
address for this board. Retest.
2807 ABRT The board is administered but not enabled on the ip-interfaces form.
1. Use the change ip-interfaces location to enable the board.
2. Retest the board.
Table 495: Test #1511 Verify NIC Options (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4