Communication Manager Maintenance-Object Repair Procedures
1632 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1 to 88 FAIL The test failed because the MM710 interface Media Module and the
remote DS1 endpoint are not synchronized to the same clock rate. The
MM710 interface Media Module detected a slip alarm. The Error Code
equals the number of slips detected by the MM710 interface Media
Module since the last slip alarm inquiry test.
If the MM710 connects to a T1 network facility or to another switch, do
the following:
1. Retry the command at 1-minute intervals for a maximum of 5
times.
2. For a DS1 interface Media Module, enter the list measurement
ds1-log location command to read the error seconds
measurement.
3. Verify that both endpoints of the DS1 link are administered using
the same signaling mode, framing mode, and line coding.
4. Check the physical connectivity of the MM710 interface Media
Modules and the cable.
5. Replace the local MM710 interface Media Module, and repeat the
test.
6. Contact T1 Network Service or the technician at the remote switch
to diagnose the remote DS1 endpoint.
Table 598: TEST #144 Slip Alarm Inquiry Test (continued)
Error
Code
Test
Result
Description/ Recommendation
2 of 4