Table 147: ASAI cause values
Code Explanation Recommendation
0 Unrecognized
ASAI Protocol
Operation.
Requested ASAI protocol is not implemented by switch or adjunct.
Aux Data field of error log entry contains protocol identifier for
unrecognized operation.
1. Consult switch and adjunct documentation to determine which
set of operations is supported by switch and the adjunct.
Turning off adjunct operations not implemented by the switch
may resolve the problem.
34 No circuit or
channel
available
A resource on the switch is unavailable for a call. For BRI
endpoints, this cause value is not logged. For ASAI, this condition
means that there are no available trunks for an outgoing call
request.
1. Verify that the adjunct is administered to support the trunk
capabilities of the switch.
2. Investigate trunk-group status by issuing status trunk from
the SAT or by requesting trunk-group queries from the adjunct.
3. Perform trunk diagnostic procedures outlined in this manual.
40 Resources
not available.
No available internal resources to service switch or adjunct request.
Exceeds system transaction capacity for adjunct or switch.
1. May require re-engineering of adjunct services.