Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
CLAN-BD (Control LAN Circuit Pack)
Issue 1 June 2005 807
2012 ABRT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1,
2
FAIL
FAIL
The buffer level is nearly exhausted.
The C-LAN is congested, and no buffers are available.
1. Retry command at 1-minute intervals up to 5 times.
2. If command continues to fail, examine the C-LAN port measurements
to determine what ports are heavily utilized and the processor
occupancy of the circuit pack.
Low processor occupancy when C-LAN congested indicates circuit pack
failure.
1. If the problem persists, reset the circuit pack with reset board
location.
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the C-LAN is congested due to traffic
load.
1. To relieve congestion in the short term, selectively busyout ports
(busyout port location) on the Control LAN circuit pack.
2. To achieve a more permanent resolution, it may be necessary to move
ports on this circuit pack to other Control LAN circuit packs.
3. Consider replacing affected C-LAN ports with new ports.
3 FAIL The C-LAN circuit pack is not operating normally and is congested.
PASS Hardware setting and attached cable type match C-LAN circuit pack
administration. The circuit pack detects no errors.
Table 276: Test #600 Congestion Query Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2