TBRI-PT (ISDN Trunk-Side BRI Port)
Issue 1 June 2005 2301
Table 826: TEST #1244 Slip Alarm Inquiry Test
Error
Code
Test
Result
Description/ Recommendation
ABRT Internal system error
2000 ABRT Response to the test request was not received within the allowable time
period.
1. If Error Type 1538 is present in the Error Log, follow the
maintenance strategy recommended for this Error Type.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 to 88 FAIL The media module and the remote endpoint are not synchronized to the
same clock rate, which has generated the Slip alarm. The Error Code
equals the number of slips detected by the MM720 since the last Slip
Alarm Inquiry Test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the media module is a MM720, enter the list measurement
ds1-log GGGVSpp command to read the error seconds
measurement.
3. Verify that both endpoints of the link are administered using the
same signaling mode, framing mode, and line coding.
4. Check the physical connections of media modules and cable.
5. Replace the media module and repeat the test.
6. Contact Network Service to diagnose the remote endpoint.
PASS No Slip alarm is detected on the media module.
0NO
BOARD
The media module is not administered.
Run Test #53.
If the test continues to return NO BOARD, escalate the problem.