Communication Manager Maintenance-Object Repair Procedures
1792 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Hardware Error Log Entries and Test to Clear Value
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description and follow its procedures.
b. Error Type 1: Within the last minute, packet circuit packs have reported errors that indicate
a possible packet bus failure. The Aux Data value is 1 or 2, indicating that only one or more
than one Packet circuit pack (respectively) have reported a possible packet bus failure.
c. Error Type 513: The Maintenance/Test packet bus port (M/T-PKT) for this port network has
determined that there are more packet bus faults than the port can correct. The Aux Data
value indicates the number of faulty leads.
d. Error Type 1793: Packet circuit packs have detected possible packet bus failures via in-line
error or via background test failure. Examine the Error and Alarm logs for more specific
PKT-BUS errors.
Table 664: PKT-BUS Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
1
1. ON-BOARD indicates a problem with the packet bus itself.
Test to Clear Value
0 (a) 0 Any Any Any test pkt port-network
1 (b
) 1–2 Packet circuit
pack Audit (#570)
MAJ ON test pkt port-network P l r
2
513 (c
)1–2
4
Maintenance/Test
Circuit Pack
Query test (#572)
MAJ ON test pkt port-network P l r
2
1793 (d
) Any None
2049 (e
) 1–3 Maintenance/Test
Circuit Pack
Query test (#572)
MIN ON test pkt port-network P l r
2
2305 (f
)1–2
4
Maintenance/Test
Circuit Pack
Query test (#572)
test pkt port-network P l
3329 (g
) 1–7 none WRN ON test pkt port-network P l
3585 (h
) Any none MIN ON test pkt port-network P l
3841 (i
) Any none MIN OFF