Communication Manager Maintenance-Object Repair Procedures
1756 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0 appears in the Error Log only if a Digital Line circuit pack that has ports
administered has been removed since the Error Log was last cleared. Make sure that the
circuit pack has been re-inserted.
b. Error Type 1, Aux Data 40987 indicates an off-board problem detected by the port circuit,
and may result in a noisy port or link. See note n for recommendations.
Note:
Note: Refer to the DEFINITY® Communications System Generic 1 and Generic 3i
Wiring, 555-204-111.
c. Error Type 1, Aux Data 1 - 20 is logged when at least 15 off-board problems have been
detected with the link to the data module. Each error detected increments an on-board
counter. The aux data gives the value of this counter divided by 15. The user could
experience a noisy port or link. See note “n” for recommendations.
Note:
Note: Refer to the DEFINITY® Communications System Generic 1 and Generic 3i
Wiring, 555-204-111.
d. Error Type 15 is an internal that occurs when an audit request fails.
e. Error Type 18 is logged when the port in question is demand busied out Make sure that the
port is released from busyout.
f. Error Type 257: problems with transmitting to the data module. This is usually an on-board
problem and can be ignored if no user complaints are received. Otherwise, check for faulty
wiring.
g. Error Type 769: EPF has been turned off due to the overcurrent condition at the data
module. See the recommendations in note n. This may also be caused by the PTC being in
the “tripped” position due to a short on the power line. You can correct this by removing the
short, unplugging the data module from the wall for about 30 seconds, and plugging it back
in.
Note:
Note: Refer to the DEFINITY® Communications System Generic 1 and Generic 3i
Wiring, 555-204-111.
h. Error Type 1537: an in-line maintenance error generated an off-board warning due to some
problem with the link to the data module. This can be ignored if no user complaints are
received. Otherwise, see Note n
for recommendations.
Note:
Note: Refer to the DEFINITY® Communications System Generic 1 and Generic 3i
Wiring, 555-204-111.
i. Error Type 2304: indicates an internal error. No action is necessary.
j. Error Type 2305, Aux Data 32770: the data equipment went off-hook while the associated
link was being initialized (in a disconnected state). Use status data-module to