Communication Manager Maintenance-Object Repair Procedures
1096 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
When problems persist, resetting the DS1 converter circuit pack via reset board may
temporarily resolve the error condition and restore service until further assistance is provided.
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 1: If the alarm is on board, then a major hardware error has occurred in a
common part of the circuit pack, not circuit or packet specific. Replace the DS1 converter
circuit pack.
If the alarm is off board, then either a major hardware error has occurred in a common part
of the circuit pack, or a good clock signal cannot be recovered from the synchronization
source. The synchronization source can be the fiber link or any one of the DS1 facilities.
1. Enter display errors and follow the associated repair procedures for any SYNC,
TDM-CLK, and SNC-BD errors.
2. Enter display errors and follow the associated repair procedures for any FIBER-LK
and DS1-FAC errors.
3. If the problem persists, replace the DS1 converter circuit pack.
c. Error Type 18: indicates that the DS1 converter circuit pack has been busied out via
busyout board. To resolve this error, release the DS1 converter circuit pack via the
release board.
769 (q
) 7 Failure Audit test
(#949)
MIN ON test board location sh r 1
1281(r
) Failure Audit test
(#949)
MIN OFF test board location sh r 1
1537 (s
) Failure Audit test
(#949)
MAJ OFF test board location sh r 1
1793 (t
) Failure Audit test
(#949)
MAJ OFF test board location sh r 1
2049 (u
) Failure Audit test
(#949)
MAJ OFF test board location sh r 1
3329 (v
) Failure Audit test
(#949)
WRN OFF test board location sh r 1
Table 373: DS1 Converter Board Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
SAT Test to Clear Value
2 of 2