CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005 829
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface circuit
pack or media module to assure that the trunk’s translation is correct. Translation updates
include the following data: trunk type (in/out), dial type, timing parameters, and signaling bits
enabled. The port audit operation verifies the consistency of the current state of trunk.
Table 284: Test #36 Port Audit and Update Test
Error
Code
Test
Resul
t
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test were not available. The port
may be busy with a valid call.
1. Enter display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is active, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error
log for error type 1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1006 ABRT The DS1 CO trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, enter release trunk to put
the trunk back in service, and then retry the test.
2000 ABRT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.