Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 June 2005 635
The test aborts if the ATM-TRK circuit pack is supplying synchronization.
Table 214: ATM Board Reset (#1256)
Error
Code
Test
Result
Description / Recommendation
1005 ABRT Wrong circuit pack configuration to run this test. The ATM CES
Trunk Interface circuit pack provides timing for the system and
cannot be reset without major system disruptions.
1. Set synchronization to another ATM CES trunk circuit pack
or to the Tone-Clock circuit pack and test again.
1015 ABRT Test cannot be run because the ATM-TRK circuit pack has not
been busied out.
1. Busyout out the circuit pack (busyout board location).
2. Repeat the test (test board location long).
None ABRT Could not allocate the required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2. If the test continues to abort escalate the problem.
2000 ABRT Sanity test timed out.
1. Wait 5 minutes. Then see if ATM-TRK circuit pack is visible
to the system by running list configuration all.
2. If the ATM-TRK circuit pack is visible (list
configuration all), run the test again, and escalate if
the problem recurs.
3. If the ATM-TRK circuit pack is not visible to the system (list
configuration all), re-seat the ATM-TRK circuit pack,
and retest.
4. If the ATM-TRK circuit pack is still not recognized by the
system, replace the board.
2100 ABRT Could not allocate required system resources
1. Retry the command up to 5 times at 1-minute intervals.
2500 ABRT Internal system error
1. Try to reset the circuit pack with reset board location.
1 of 2