TIE-DS1 (DS1 Tie Trunk)
Issue 1 June 2005 2273
b. Error Type 1: the DS1 Interface circuit pack or media module detects a hardware error on
the DS1 tie trunk. This error can be caused by incompatible translations. Make sure the
parameters administered on the DS1 circuit pack or media module form match those
administered on the far-end switch. See Administrator Guide for Avaya Communication
Manager, 03-300509 for details.
The Aux Data field indicates the following hardware Error Types:
If every administration parameter between the switch and the far end match and these
errors continue to recur, follow normal escalation procedures.
c. Error Type 15: this is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated errors (if any).
d. Error Type 18: the DS1 tie trunk has been busied out with busyout trunk grp#/mem#.
No calls can be made on this trunk except for the Facility Access Test call. See
Administrator Guide for Avaya Communication Manager, 03-300509.
e. Error Type 19: the far end may be out-of-service, or the Electronic Tandem Network may
be busied out.
f. Error Type 130: the circuit pack or media module has been removed or has been insane for
more than 11 minutes. To clear the error, reinsert or replace the circuit pack or media
module.
g. Error Type 257: the DS1 Interface circuit pack or media module detects a hardware error
on the DS1 tie trunk. The trunk cannot communicate with the far end because it is unable to
interpret digits sent from the far-end switch. The Aux Data field indicates the following:
Check with the far-end switch or operating company for proper trunk connection.
h. Error Type 513: the DS1 Interface circuit pack or media module detects a hardware error
on the DS1 tie trunk. The trunk is in-service/active and waiting for an “on-hook” from the
far-end switch. No calls can be routed over the trunk while it is in this state. Aux Data 57392
indicates no external release on PBX disconnect. Check with the far-end switch or
operating company for proper trunk connection.
57476 On-hook before wink
57477 On-hook before ready to receive digits
57485 Wink too short for valid signal
57487 The timer expired while waiting for an off-hook signal from the far end as
a response at end-of-digits dialing. Check the far-end switch for related
problems.
57473 The rotary dial rate is below 8 pulses per second.
57474 The rotary dial rate is above 12 pulses per second.