Communication Manager Maintenance-Object Repair Procedures
1460 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Audit and Update Test (#36)
This test sends port level translation data from the switch processor to the DS1 interface circuit
pack or media module to assure that the trunk’s translation is correct. The port audit operation
verifies the consistency of the current state of trunk kept in the DS1 interface circuit pack or
media module and in the switch software.
Table 526: Test #36 Audit and Update Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1018 ABRT Maintenance is disabled on this trunk.
1. Enable maintenance by entering y in the Maintenance Tests field
on the change trunk-group form.
2000 ABRT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS Trunk translation has been updated successfully. The current trunk states
kept in the DS1 interface circuit pack or media module and switch software
are consistent.
If the trunk is busied out, the test will not run, but will return PASS. To verify
that the trunk is in-service:
1. Enter status-command to verify that the trunk is in-service. If the
trunk is in-service, no further action is necessary. If the trunk is
out-of-service, continue to Step 2.
2. Enter release-trunk to put trunk back into in-service.
3. Retry the test command.
1 of 2