CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005 825
Table 283: Test #7 Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT The test was aborted. System resources required to run this test were not
available. The port may be busy with a valid call.
1. Use display port location to determine the trunk group/member
number of the port. Use status trunk to determine the service state
of the port. If the port is active, wait until it is idle before testing.
2. If the port status is active but the port is idle (no calls), check the error
log for error type 1025 (see the error log table for a description of this
error and required actions). The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out of service due
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic
and the port status is idle, retry the command at 1-minute intervals up
to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present, or some of the
Tone Detectors may be out of service.
1. Use list measurements tone-receiver to see basic information
about the system's tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port has been seized by a user for a valid call.
1. Use status station or status trunk to determine when the port
is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.