ASAI-EPT
Issue 1 June 2005 491
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate errors associated with the circuit pack and port first. Clearing these error codes may
also clear errors against the endpoint. When every circuit pack and port error has been cleared,
but errors still exist against the endpoint, investigate errors in the table below.
BRI Layer 3 Query Test (#629)
This test is not used by the ASAI-ADJ MO. For information about this test, see BRI-SET,
Various Adjuncts on page 708.
69 Requested
facility not
implemented
Requested service not supported in switch or endpoint.
1. Consult switch and endpoint documentation to determine
service support.
79 Service or
option not
implemented
Requested service or option (or combination of selected options) is
not supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct documentation to determine ASAI
service and options supported by both switch and adjunct.
Re-administration of the switch-administered capabilities (see
Customer Optional Feature screen) or those of the adjunct may
be necessary to correct the problem.
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and
the adjunct. See the CallVisor protocol reference manual.
87 Internal switch
audit
There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the
data inconsistency.
Table 147: ASAI cause values (continued)
Code Explanation Recommendation
3 of 3
Order of Investigation Short Test
Sequence
Long Test
Sequence
D/ND
Signaling Link Status test (#626) X X Nondestructive