DAT-LINE (Data Line Port)
Issue 1 June 2005 873
1002 ABRT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors.
1. Resolve any TDM-BUS errors.
2. If the system is not handling heavy traffic, retry the command at
1-minute intervals up to 5 times.
1003 ABRT The system could not allocate a tone receiver for the test. The system
may be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV and TONE-PT errors.
2. If neither condition exists, retry the command at 1-minute intervals up
to 5 times.
1004 ABRT The port was in use on a valid call.
1. Determine whether the port is available for testing (status
data-module).
2. When available, retry the command at 1-minute intervals up to 5
times.
1020 ABRT An existing Error Type 769 on this port prevented the test from running.
1. Follow the procedures for Error Type 769.
2000 ABRT Response to the test command was not received within the allowable time
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port was transmitting in error, which can cause
noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
1. Investigate user-reported troubles on this port using other port tests
and examining the ADU, external wiring, and customer equipment.
Table 297: Test #6 NPE Crosstalk Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2