Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
LOG-SVN (Login Security Violation)
Issue 1 June 2005 1487
LOG-SVN (Login Security Violation)
S8700 | 8710 / S8500
The Security Violation Notification (SVN) feature provides notification when the number of failed
attempts to access the system administration/maintenance interface meets or exceeds
customer administered threshold parameters.
A major alarm is logged whenever a security violation is detected involving an Avaya services
login ID and that login ID has been disabled as a result of detection of the security violation. The
capability to disable a login ID following detection of a security violation involving that login ID is
administrable on a per login ID basis.
Refer to the Administrator Guide for Avaya Communication Manager, 03-300509, for
information about administration required for the Security Violation Notification feature, and the
option to disable a login ID following detection of a security violation involving the affected
login ID.
Error Log Entries and Test to Clear Values
General Information about log-svn error log entries:
1. The number (1–15), that appears in the error type field, corresponds to the location of the
login in the internal login data structure.
2. The Alt Name field on the alarm report indicates the login ID associated with the security
violation and major alarm.
3. These errors/alarms are associated with a number of failed attempts to access the system
management/maintenance interface using an Avaya services login ID that meet or exceed
the customer administered threshold parameters. The associated alarm is immediately
raised as a major alarm.
MO Name in
Alarm Log
Alarm
Level
Initial SAT Command to Run Full Name of MO
LOG-SVN MAJ enable login loginID
1
1. Where loginID is the Avaya services login ID for which the security violation was detected. The
Alt Name field indicates the login ID associated with the security violation and the major alarm.
Login Security Violation
Table 534: Security Violation Notification Error Log Entries
Error
Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
1–15 None None Major OFF enable login loginID