Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
ADX8D-PT (AUDIX Digital Port)
Issue 1 June 2005 347
b. Error Type 1, Aux Data 40987: the user may experience a noisy port or link, due to an
off-board problem that is detected by the port circuit. If so, replace the circuit pack (see
caution at the beginning of this section). Once the problem is resolved, the alarm is retired
after a predetermined time.
c. Error Type 1, Aux Data 1 to 20: At least 15 off-board problems have been detected with
the link to the voice port. When an error with the link is detected, an on-board counter is
incremented. Also see Note (a).
d. Error Type 15: internal type error that occurs when an audit request fails.
e. Error Type 18: the port is busied-out by command. Use release port location to
release the port.
f. Error Type 23: the circuit pack is administered but not physically installed. The alarm will
clear when a circuit pack is inserted.
g. Error Type 130: the circuit pack was removed or has been insane for more than
21 minutes. To clear the error, reinsert or replace the AUDIX circuit pack (see Caution at the
beginning of this section).
h. Error Type 257: Something is interfering with transmission to the voice port. This is usually
an on-board problem and can be ignored if there are no user complaints.
i. Error Type 513: AUDIX is not available to the switch, possibly due to a busyout on the
AUDIX system. See EMBEDDED AUDIX System Maintenance, 585-300-110, if necessary.
j. Error Type 1537: An in-line maintenance error has generated an off-board warning due to
some problem with the link to the voice port. This can be ignored if there are no user
complaints. If the problem persists, replace the circuit pack (see Caution at the beginning of
this section). Once the problem is resolved, the alarm is retired after a certain period of time.
k. Error Type 2305: the link between the circuit pack and the voice port successfully reset. No
craft action is necessary.
l. Error Type 3840, Aux Data 40965: no voice ports are connected to the EMBEDDED
AUDIX circuit pack. No maintenance action is required.
m. Error Type 3840, Aux Data 41029: the message buffer in the circuit pack is full.