DS1C-BD
Issue 1 June 2005 1107
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316 ABRT Fiber link is not administered. Administer the DS1 converter fiber link via
add fiber-link.
2321 ABRT DS1 converter circuit pack is not busied out. Busyout the DS1 converter
circuit pack via busyout board.
2332 ABRT With this system configuration (unduplicated PNC), the test was aborted
because it cannot be run at the far end when there is only one DS1-FAC
available. (The link would be lost, and no test results would be seen at the
media server). Run the test at the other end of the DS1C complex.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Table 376: Test #789 Far-End FOT (Lightwave Transceiver) Loop-Back Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3