Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
Communication Manager Maintenance-Object Repair Procedures
1102 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
The reset sequence will take about one minute to complete.
Table 374: Test #787 Reset Board
Error
Code
Test
Result
Description / Recommendation
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABRT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABRT The timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316 ABRT Fiber link is not administered.
Use add fiber-link to administer the DS1 converter fiber link.
2321 ABRT DS1 converter circuit pack is not busied out.
Use busyout board to busyout the DS1 converter circuit pack.
2500 ABRT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
PASS Reset sequence was executed successfully. (However, this test result does
not indicate whether the firmware diagnostic tests passed.)
1. Enter display errors to check the error log for any failed diagnostic
firmware tests. (This is indicated by an entry of Error Type #1 for this
circuit pack’s location.)
2. Enter display alarms to check the alarm log for any ON-BOARD
MAJOR alarms.
0
NO
BOARD
The system software found no board.
1. Reset the board.
2. Remotely retry the command.