Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
DIG-IP-STN (Digital IP Station)
Issue 1 June 2005 921
Digital Terminal Lamp Update (#16)
This test updates internal lamp states that can or cannot be shown on the actual PC graphical
user interface. The lamp updates run only if the station is in-service. The status of the station is
checked and the lamp updates are blocked from taking place if the station is not in the
in-service state. This test does not affect the status of the Message Waiting lamp.
Table 315: Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
ABRT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 ABRT This port could have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port via release station
extension and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3 ABRT Station could be in ready-for-service or out-of-service state.
1. Use status station to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABRT System resources required to run this test are not available. The port could
be busy with a valid call.
1. Use display port location to determine the station extension of
the port. Use status station to determine the service state of the
port. If the port is in use, wait until it is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals
up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The message to light every station lamp was successfully sent to the port.