DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005 989
NPE Connection Audit Test (#50):
The system sends a message to the on-board microprocessor to update the network
connectivity translation for all the Network Processing Elements (NPEs) on the circuit pack.
Table 340: Test #50 NPE Connection Audit Test
Error
Code
Test
Result
Description / Recommendation
None,
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019 ABRT Test already in progress.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit pack’s NPEs have been updated with their translation.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use add ds1
location to administer the DS1 interface if it is not already
administered.
2. If board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. Enter busyout board
4. Enter reset board
5. Enter release board
6. Enter test board long
This should re-establish the linkage between the internal ID and the
port.