ANL-16-L (16-Port Analog Line)
Issue 1 June 2005 385
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily maintenance. If this
ringing is disturbing the customer or the terminal equipment, it should be disabled in the Tests
field of the change station extension screen. Be aware that this action will also disable
Tests #6, 7, 161, and 35.
Error Log Entries and Test to Clear Values
Table 112: 16-Port Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test Alarm
Level
On/
Off
Board
Test to Clear Value
0 (a) 0 Any Any Any test port location sh r 1
1(b
) 40960
40975
40977
none
15(f
) Any Audits and Updates
(#36)
18 0 busyout station
extension
WRN ON release station extension
130(g
) None WRN ON test port location sh
257(h
) 40973 none
513(i
) Station Present (#48) WRN OFF test port location sh r 2
769 Battery Feed test
(#35)
MIN
WRN
1
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set options.
ON test port location sh r 2
1025 Looparound (#161) MIN
WRN1
ON test port location l r 2
1281 Conference test (#7) MIN
WRN1
ON test port location l r 2
1537 NPE Crosstalk (#6) MIN
WRN1
ON test port location l r 2