FIBER-LK (Fiber Link)
Issue 1 June 2005 1273
118 FAIL The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 18. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3329, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3329, replace
the SNI in slot 18.
119 FAIL The SNI circuit pack (Endpoint 1) cannot communicate with the equipped
SNI in slot 19. Use list fiber-link to see a fiber link’s endpoints.
1. Perform the Fiber link fault isolation
in Chapter 4: General
troubleshooting in Maintenance Procedures (03-300192). This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 3585, replace the
SNI being tested. (Replacing an SNI may be service interrupting.
Refer to the SNI-BD section for the procedure to replace an SNI.) To
view SNI-PEER errors, use display errors with category
PNC-PEER. Retry the command.
3. If the SNI being tested still has SNI-PEER Error Type 3585, replace
the SNI in slot 19.
Table 440: Test #759 Configuration Audit (continued)
Error
Code
Test
Result
Description / Recommendation
9 of 22